The one-piece interior removes and re-installs easily. A: The input terminals do not show any signs of being used, but the output terminals were definitely previously connected to a load center. Please try again later. Site design / logo 2023 Stack Exchange Inc; user contributions licensed under CC BY-SA. It's foolhardy to scrimp on panel spaces - GO BIG. Learn more:www.homesphere.com, ABB (ABBN: SIX Swiss Ex) is a technology leader in electrification and automation, enabling a more sustainable and resource-efficient future. Never run out of spaces again! High-rise residential application. It is bad. It indicates the numbering. Modern subpanels are significantly larger due to wire bending space rules. Access My Account, Order History, Lists and more here. Calgary, AB, T2Z 3X2, Phone number : Spend the $3600, get the service upgraded to 200A, fix the panel, and tag it onto your listing as a selling point. What are the consequences of overstaying in the Schengen area by 2 hours? I think the "$600 bid" is almost certainly based on some assumptions about your panel which are not true, and it's likely to increase to near the $3600 bid when they see the insides of your panel. All (reasonably large) panels sold today are either Main-Lug, Main-Breaker, or Convertible. There isn't a chance in the world I would add additional load to the existing over current protection. There is no need to suffer a "Main-Nothin'" panel anymore. Error posting question. Sign In to access your account information. Please call us at: 1-800-HOME-DEPOT (1-800-466-3337), Please enter in your email address in the following format: you@domain.com. They ensure that the live space is closed off to prevent injury and electrical damage. Would the reflected sun's radiation melt ice in LEO? The input terminals do not show any signs of being used, but the output terminals were definitely previously connected to a load center. Help others learn more about this product by uploading a video! : By clicking Post Your Answer, you agree to our terms of service, privacy policy and cookie policy. Can a whole house surge suppressor be installed in a sub panel? . The first two breakers are #1 in the upper left, #2 an essentially identical breaker in the 2 full spaces in the upper right, and #3 the mid-left breaker marked "MAIN". All Rights Reserved. These accessories are used to customize, mount, and enhance the safety of GE panelboards and load centers. General Electric | sku: TLM1220RCU. picture please, would help us to help you. Install a "main breaker conversion kit" at the top of the box and "make space"=$600. They also have a horizontal handle to allow for top or bottom feed applications. The clip works, I believe the person who decided on the cost must be related to Biden. There is a raised tab on each of the blades that block it from being able to seat. Free shipping. * Not to be confused with, and not compatible with, Eaton BR. Reviewed in the United States on January 10, 2022. Q: Please call us at: 1-800-HOME-DEPOT (1-800-466-3337), Please enter in your email address in the following format: you@domain.com. Bonus points if you plan it so you can cut over the subpanel to be a future main panel. Connect and share knowledge within a single location that is structured and easy to search. All Rights Reserved. Could very old employee stock options still be accessible and viable? GE PowerMark Gold 100-Amp 22-Spaces 12-Circuit Indoor Main Breaker Load Center (Value Pack) Item # 214802 Model # TM1210CCUG1K Shop GE 35 GE PowerMark Gold 100-Amp 22-Spaces 12-Circuit Indoor Main Breaker Load Center (Value Pack) Shop GE 35 Add to Cart Specifications $84.97 when you choose 5% savings on eligible purchases every day. Custom Field. Can I install a 60A main breaker in a load center rated for 125A? Their unique features enable a safe, fast and easy installation. It looks like WhatsApp is not installed on your phone. Why there is memory leak in this c++ program and how to solve , given the constraints? Effortless installations are possible with GE PowerMark Gold Load Centers. They're used with circuit breakers to protect circuits from overcurrents. Hard to find and wondering if OK to use very common THQL series as seem to slot right in. I think some one may have given you ??? What size sub-panel and wire do I need for my three-season room? Ackermann Function without Recursion or Stack. Sorry, we were unable to perform your search at this time. Learn more about Stack Overflow the company, and our products. Brief content visible, double tap to read full content. Reviewed in the United States on August 6, 2017, Reviewed in the United States on May 3, 2021. All must be shut off to shut off the power. Manufacturer:ABB. Feel free to use a GE Qline panel that supports double-stuffs, so you can keep using the same breakers. Reviewed in the United States on April 28, 2013. Local store prices may vary from those displayed. PS: The service barrier insulates the energized lugs when the main is turned off to keep people safe. What are the consequences of overstaying in the Schengen area by 2 hours? Please try again. A: I think the answer is not much or at least not much good. Whether you are working on a new residence or a renovation project, our high-quality and robust load centers are. Clearly this was a quality installation. You have to check the panel enclosure label or existing breaker model. These load centers are used in high-voltage commercial and industrial . Oh, sorry, i should've been clearer-- i don't need to "open" the oven breaker to kill all the power, it's just that what's labelled "Main" doesn't kill power to the oven or to the sub panel. They can be used at the service entrance in low-voltage residential, commercial, and industrial applications. Product Details The GE Power Mark Gold 200 Amp 4-Space 8-Circuit Main Breaker Meter Socket Outdoor Load Center installs easily and delivers dependable performance. Compatible with GE standard, GFCI and AFCI circuit breakers. Please clarify wiring to and for remote pool load center, Wiring for switched NEMA 6-20R and 5-20R in same box in garage, Can this CH breaker panel handle tandem breakers, 15A DF breaker keeps blowing at sub panel hot connection point. Instead, our system considers things like how recent a review is and if the reviewer bought the item on Amazon. So it's worse than "need to squeeze in another breaker", it's actualy you need to move the dryer breaker away so you can restore the breaker in that location to a traditional full-size breaker as is required by the diagram. www.abb.com, ABBs Electrification Business Area is a global leader in electrical products and solutions, operating in more than 100 countries, with over 200 manufacturing sites. Then, one of those breakers feeds an "internal subpanel" area with any number of breakers. The one-piece interior removes and re-installs easily. We are shaping the future trends of electrification, differentiating through technological and digital innovation while delivering an outstanding experience through operational excellence for our customers across utilities, industry, buildings, infrastructure and mobility. Please try again. GE TM3210CCU - 100 Amp NEMA 1 PowerMark Gold Main Breaker Load Center. PowerMark Gold Feed Thru Lug Include feed-thru lugs that can be used on main lug or main breaker interiors to feed additional load centers downstream. . What to do about breaker that triggers main panel, and breaker that's stuck? Hard to say based only on what you show and describe here. With PowerMark* Gold Load Center Kits and Meter Socket Load Center Kits, there is no need for a separate generator panel. (main breaker retrofit possible). This load center is UL listed and ANSI Certified. We can't really know exactly what you have without seeing what's inside. , Manufacturer Access My Account, Order History, Lists and more here. The companys solutions connect engineering know-how and software to optimize how things are manufactured, moved, powered and operated. he clearly mutilated the panel in order to make that dryer breaker go there. I'm looking to add central A/C to my 1970s era home. I take it you have a main-nothin' subpanel that has only branch circuit bus stabs, no main lugs, no main breaker it is meant to have a breaker installed that is back-fed, correct? The $3600 may be addressing other deficiencies like service size etc. Unable to add item to List. Manufacturer #:TMC30412C. New, pulled from a new box, not manfacturer new. Customer Reviews, including Product Star Ratings help customers to learn more about the product and decide whether it is the right product for them.Learn more how customers reviews work on Amazon. Asking for help, clarification, or responding to other answers. Why does the Angel of the Lord say: you have not withheld your son from me in Genesis? Drift correction for sensor readings using a high-pass filter. Making statements based on opinion; back them up with references or personal experience. It has one leg in the Rule of Six area, and one leg in the subpanel area. . Indoor NEMA 1 enclosure with combination surface/flush front. Maximum amount of digits: 6. I still dont have a clear picture of how the $600 bid guy was going to accomplish what he wanted to do and be able to pull a permit. Interval: 1 Availability: Log In for Availability Your Price: Login For Price Qty Add To Cart Add To Product Group Select Item Compare EATON 3BR1224B100R These load centers are used in high-voltage commercial and industrial applications. I added a few photos, anything change for you? Note that the #3 breaker actually sits in the subpanel area and is fed via those two fat wires. $164.63. Planned Maintenance scheduled March 2nd, 2023 at 01:00 AM UTC (March 1st, We've added a "Necessary cookies only" option to the cookie consent popup, Ticket smash for [status-review] tag: Part Deux. GE neutral and ground lug kits are used to add or replace lugs in a GE load center or panelboard. GE Energy Industrial Solutions TLM612RCUP Convertible Main Lug Outdoor Load Center, 125-Amp 2 Square D - HOM2448M100PCVP Homeline Load Center with Cover, 100-Amp Convertible Main Breaker, 1-Phase, 24-Space, 48-Circuit, Indoor - Value Pack Plug-on Neutral Ready 809 $10900$185.10 FREE delivery Mon, Jan 23 Only 11 left in stock - order soon. GE THQLRK2 Main Breaker Retainer, for Use with 6 to 8 Circuit PowerMark Gold Loadcenters with THQL Breakers Visit the GE Store 4 ratings $976 About this item For use with 6 - 8 circuit PowerMark gold loadcenters with THQL breakers Screw-down mounting design Frequently bought together + Total price: Add both to Cart What tool to use for the online analogue of "writing lecture notes on a blackboard"? People with very old GE panels have had mixed success using modern THQL full-width breakers. You don't need a main breaker unless this building is detached (stand-alone) from the building the main breaker is in. GE Outdoor Main Lug Circuit Breaker Panel 125 . Most AHJs don't like to put impediments in front of panel upgrades, because some panels (FPE, Zinsco) are scary dangerous and need to go. Quick view Details. Products shown as available are normally stocked but inventory levels cannot be guaranteed, For screen reader problems with this website, please call 1-800-430-3376 or text 38698 (standard carrier rates apply to texts), Number of Spaces: 12 in Main Breaker Box Kits, Homeline 200 Amp 30-Space 60-Circuit Indoor Main Breaker Plug-On Neutral Load Center with Cover(HOM3060M200PCVP), QO 200 Amp 2-Pole Outdoor Circuit Breaker Enclosure with QOM2200VH Breaker, PowerMark Gold 200 Amp 8-Space 16-Circuit Outdoor Main Breaker Circuit Load Center Panel, Homeline 200 Amp 40-Space 80-Circuit Indoor Main Breaker Qwik-Grip Plug-On Neutral Load Center with Cover - Value Pack, 200 Amp 32-Space 64-Circuit Main Breaker Outdoor Load Center Contractor Kit, Homeline 200 Amp 8-Space 16-Circuit Outdoor Main Breaker Load Center with Feed-Thru Lug, QO 200 Amp 42-Space 42-Circuit Indoor Main Breaker Plug-On Neutral Load Center with Cover- Value Pack, PN Series 200 Amp 40-Space 40-Circuit Main Breaker Plug-On Neutral Load Center Indoor with Copper Bus, BR 200 Amp 40-Space 80-Circuit Main Breaker Indoor Plug On Neutral Load Center Contractor Load Center and Breaker Kit, 100 Amp 20-Space 20-Circuit Main Breaker Indoor Load Center Contractor Kit, Homeline 100 Amp 30-Space 60-Circuit Indoor Main Breaker Plug-On Neutral Load Center with Cover(HOM3060M100PC), SN Series 100 Amp 20-Space 20-Circuit Main Breaker Plug-On Neutral Load Center Value Pack, Limit the Use of My Sensitive Personal Information, Do Not Sell or Share My Personal Information. GE panel mount surge protectors divert excess current to the ground in the event of a power surge and are used in GE PowerMark load centers for service entrance or subpanel applications. Need Help? There are 3 double-pole switches that must be thrown to truly power off to the whole house (oven, "main", and the sub panel). Asking for help, clarification, or responding to other answers. It only takes a minute to sign up. Need Help? Sponsored. Obviously this necessitates a breaker compatible with the bolt-down hardware. The companys solutions connect engineering know-how and software to optimize how things are manufactured, moved, powered and operated. These GE THQL main lug load centers distribute power downstream from main breakers and are used when all the circuit slots in the main breaker load center are full or when a remote panel is desired. So I have no idea WHAT you have there, and most likely the guy who thought he could do this by simply moving the main to gain two new slots was thinking that too. It will help a lot if you leave them lots of spaces in the new panel. The load center includes a sturdy tin-plated copper buss bar and a galvanized box for increased durability and reliability. WARNING: This product can expose you to chemicals including Lead which is known to the State of California to cause cancer and birth defects or other reproductive harm. They provide direct protection for the entire panel and all attached loads. It is narrow "double-stuff" breakers not a full-sized one." Betcha didn't know that LOL, yeah now with more pics it's definitely a split bus panel that was relying on the rule of 6 for the upper half, but as Harper pointed out, your dryer and sub panel are wired wrong. Trying to upgrade breaker from P215 to P220. Product Reviews. Find tips and inspiration for your home improvement projects. Adding another 30A/40A drop for A/C is probably pushing it. So in reality you may have something here that someone before you hacked and screwed up, so my guess is that the $3600 quote was from someone who DID understand what you have here and would only do it as a complete rip and replace to modern codes, done with pulling a permit, inspections etc. They prevent water damage in outdoor electrical systems. Features ground fault circuit interrupter, factory-installed neutral, and ground bar, and a weather-proof enclosure making it the smart choice for pools and spas. Brand-wise, crossing brands is not allowed (except for UL Classified breakers), so if you own any GFCI or AFCI to be used in the new panel, use that brand of panel. Suspicious referee report, are "suggested citations" from a paper mill? This is actually a variant of the "normal" way to do this, because normally a Main breaker is SEPARATE from the rest of the usable plug-on panel bus space. The main breaker retainer secures a two-pole branch breaker on the interior. If you have any thought to a generator interlock, only consider panels for which one is available. A Rule of Six panel has a "Main Breaker" area with up to six main breakers. Isolated ground kits also include an insulator for electrical protection. Oh wow, your dryer breaker straddles the split bus that's interesting. All six have their buses energized at all times. Advanced plug-on neutral circuit breakerswith ReliaLock connection feature, elevated integrated ground bars enable a safer and easier, installation. Hard to tell what the feeder wire is, but it looks like 2AWG to me. 100% rated split neutral on each side. Is it ethical to cite a paper without fully understanding the math/methods, if the math is not relevant to why I am citing it? This website uses cookies to ensure you get the best experience on our website. These circuit breaker filler plates cover unused space in GE panelboards and load centers. The UL-listed load center has holes rated 100% split neutral on each side that are compatible with #14-4 wire. Product Videos. Your question might be answered by sellers, manufacturers, or customers who bought this product. Please use a different way to share. Self-adjusting dead-front cover. Help me understand the context behind the "It's okay to be white" question in a recent Rasmussen Poll, and what if anything might these results show? Again, this was part of a larger project (heating/AC), so the information I was after was what would adding a main breaker do. For more information visithttps://go.abb/electrification, ** All third party trademarks are the property of their respective owners, Installation, Commissioning & Maintenance, PowerMark Gold Single Phase - Canadian CSA, Full-length neutrals are easier to wire, reducing installation time and cost, Sturdy copper bus and galvanized box increase durability and reliability, Tangential knockouts reduce conduit bending time, Back keyholes and slotted side holes simplify mounting, One-piece interior that can be removed and reinstalled easily, Tie bar may be removed to splitNeutral/ground, Accepts GE Q-Line branch breakers, including GEs exclusive 1/2" THQPs, Suitable for use as Service Entrance Equipment when installed in accordance with the National Electric Code, Capable of holding 2 - 42 feeder circuits, Single Phase, Three Wire, 120/240 VAC, 22 kAIC Rated. They allow a main lug panel to be used in service entrance applications when desired. , ASIN They're typically used in residential and commercial applications. By the way, whoever the genius is who stuck numbers on the breakers, did not read the panel labeling. Torsion-free virtually free-by-cyclic groups. It had a 100 amp double pole breaker at top (Type TQAL-AC) that may have been forcibly inserted as now can't get it or other similar breakers re-inserted. Can patents be featured/explained in a youtube video i.e. Only digits are allowed. OP may also need to consider a service upgrade. Menu. Browse other questions tagged, Start here for a quick overview of the site, Detailed answers to any questions you might have, Discuss the workings and policies of this site. : Three phase. Very bad! There is a raised tab on each of the blades that block it from being able to seat. The electric panel is a GE Load Center, 125 Amp max. Please check compatibility before purchasing. You Save $15.05 with Mail-In Rebate. So you may have something called a "Split Bus" panel, which makes this entire thing complicated if that's the case. How to add GFI circuit under sink for water filter? Accepts 40-225 Amps main breaker; Capable of . According to GE's application guide, http://apps.geindustrial.com/publibrary/checkout/DET-. McHandiman Electric Plus However you will probably not be able to use double-stuff breakers going forward because AFCI or GFCI is required on almost every circuit. $452.46 / EA. Once you do that, the two slots that hold the Main now become available to have a new breaker(s) installed in them. Honestly at this point, you might as well go "in for a penny, in for a pound". It also analyzed reviews to verify trustworthiness. GE load centers include a sturdy tin-plated copper buss bar and a galvanized box for increased durability and reliability. It is backfeeding the subpanel area. Also whoever put the double-stuff in the upper right, don't invite him back either. So whomever first did this knowingly sacrificed 2 breaker slots in order to avoid buying the Main Breaker Mounting Kit this panel required to put the Main AHEAD of the bus bars and feeding them. The 2 pole 50A breaker what has the word "Main" written next to it is probably the main breaker for all of the power coming from your utility meter, or al least may have started out that way at one time. Close Sign In Find many great new & used options and get the best deals for GE PowerMark Gold Load Center Breaker Box 100 AMP breaker Included Free Shipping at the best online prices at eBay! GE Energy Industrial Solutions TM2020CCUPL2 Main Breaker Load Center, 200-Amp Visit the GE Store 4 ratings $37995 About this item It Is 200A Main Breaker Load Center With 12 - 20A 1/2" Breakers 30A 1/2" Breaker And With 50A 1/2" Breaker Brand Name: Ge Energy Industrial Solutions See more product details + + Total price: $461.69 $379.95 $39.99 Acceleration without force in rotational motion? Why is the article "the" used in "He invented THE slide rule"? When it comes to GE Panelboard & Load Center Accessories, you can count on Grainger. Main Breaker - Miswired connection Question. The GE 200 Amp 20-Space 40-Circuit Main Breaker Outdoor Load Center Contractor Kit is pre-packaged with a selection of circuit breakers. Can the Spiritual Weapon spell be used as cover? Crazy span. By clicking Accept all cookies, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy. The bus isn't great at dissipating heat from computers, HID lighting, non-linear loads. Could very old employee stock options still be accessible and viable? Order Qty: 1 Qty. rev2023.3.1.43268. Any back-fed breaker must be bolted down. SIEMENS CANADA EQ442QJ125 42 Circuit 3 Phase 4 Wire 240V 125Amp Siemens Load Center. Square D by Schneider Electric HOM2448M100PCVP Homeline 100 Amp 24-Space 48-Circuit Indoor Main Breaker Load Center with Cover - Value Pack (Plug-on Neutral Ready), , . Other double pole and single pole breakers do not . The breaker assembly appears to be unused, but not factory new. Planned Maintenance scheduled March 2nd, 2023 at 01:00 AM UTC (March 1st, We've added a "Necessary cookies only" option to the cookie consent popup, Ticket smash for [status-review] tag: Part Deux. GE Circuit Breakers at Lowes.com Electrical /Power Distribution & Circuit Protection /Circuit Breakers 41 products in GE | Circuit Breakers Popular Filters Number of Poles: 2 Square D Eaton Number of Poles: 1 Power Capacity: 20-amp Siemens Sort & Filter (1) Sort & Filter (1) Sort By Featured Best Sellers Highest Rated New Arrivals Special Offers This GE value kit includes 2 15 Amp single pole, 2 20 Amp single pole, 1 30 Amp double pole THQP 1/2 in circuit breakers. It simply must be labeled "MAIN". Browse other questions tagged, Start here for a quick overview of the site, Detailed answers to any questions you might have, Discuss the workings and policies of this site. The bids for the electric panel "upgrade" range from $600 to $3600. Square D would cost more. Home Improvement Stack Exchange is a question and answer site for contractors and serious DIYers. If you were a customer of mine and wouldn't let me rip out that equipment, I would walk away. GE Energy Industrial Solutions THQMV200D Main Breaker Kit for GE Load Centers, 200-Amp Visit the GE Store 28 ratings About this item It is 200A Main Breaker Kit For GE Load Centers Mounts Vertically To Enable Top Or Bottom Feed For Use In New TLM2020CCU Powermark Gold Main Lug Load Center Model number: THQMV200D See more product details Brief content visible, double tap to read full content. Do not use BR in a GE panel, no matter how much easier they are to find. Full content visible, double tap to read brief content. Here is what the Main Breaker Kit looks like for this; The two tabs replace the main incoming lugs, so your incoming power leads would now go to the Main breaker lugs and this connects that main breaker to the bus. Installation, Commissioning & Maintenance, PowerMark Gold Single Phase - Canadian CSA. "Upgrade" is in quotes, because I think what it boils down to is 2 choices, hence the span in price. Nothing says a back-fed breaker needs to be at the top.